Our Flat Flexible Cable ( FFC ) offers great advantages in th design and manufacture
of electronic devices and equipments.

Easy To Use
- Insertion to FFC connector
- Solder-type for solder to PCB
Flexible and Bendable
- Connecting of Electronic Circuits with Moving Parts
Miniature
- Fine Pitch and Paper-Thin Body
Reliable
- UL Approve
- FFC can tolerate 10 millions slides
Versatile
- Choices of
- No. of Conductors
- Pitch
- Conductor Size
- Strip Length
- Supporting Tape Length
- Folding to Suit Layout
Easy Logistic
- Easy to Storage and Transportation due to Light Weight and Small Volume
Low Cost
- A Cost Effective Solution for Interconnection

* Applicable UL No.
|
UL No.
|
Voltage Rating
|
Operating Temperature
|
File No.
|
|
UL 20798
|
60V
|
80°C
|
E 188165
|
|
UL 20861
|
60V
|
105°C
|
E 146835
|
* Selection Guide For Connectors (unit: mm)
|
Pitch
|
0.5
|
1.0
|
1.25
|
2.54
|
|
Conductors For Type A, B, C, D, E, F
|
Thickness
|
0.035
|
0.1
0.035
|
0.1
0.05
|
0.1
|
|
Width
|
0.3
|
0.7
|
0.8
|
0.8
1.27
|
|
Conductors For Type G
|
Thickness
|
-
|
- 0.1 (PBW)
|
-
|
|
Width
|
-
|
- 0.5 (PBW)
|
-
|

Specification
(N=No. OF conductors)
|
Item
|
Pitch=0.5mm
|
Pitch=1.0mm
|
Pitch=1.25mm
|
Pitch=2.54mm
|
| Insulation Material |
Flame retardant polyester ( white )
|
| Conductor Material |
Tin or solder plated flat rectangular copper wire
|
| Conductor Size (mm) |
0.035 x 0.3
|
0.035 x 0.7
|
0.1 x 0.7
|
0.05 x 0.8
|
0.1 x 0.8
|
0.1 x 0.8
|
0.1 x 1.27
|
Max. conductor
resistance, /mm |
1.5
|
0.85
|
0.3
|
0.52
|
0.26
|
0.27
|
0.17
|
| Total Length, L (mm) |
25 to 1,000
|
TotalLengthTolerance
(mm) |
25 to 100 ± 3
|
|
101 to 300 ± 5
|
|
301 to 600 ± 10
|
|
601 to 1,000 ± 20
|
| Pitch Tolerance (mm) |
±0.03
|
±0.08
|
±0.1
|
±0.1
|
| Total Pitch, Pt (mm) |
0.5x(N-1)±0.03
|
1.0x(N-1)±0.15
|
1.25x(N-1)±0.15
|
2.54x(N-1)±0.15
|
| Total Width, W (mm) |
0.5x(N-1)±0.07
|
1.0x(N-1)±0.12
|
1.25x(N-1)±0.2
|
1.25x(N-1)±0.2
|
| Margin Width, M (mm) |
0.5±0.1
|
1.0±0.15
|
1.25±0.2
|
2.45±0.2
|
| Terminal Thickness, T (mm) |
0.3±0.05
|
| Strip Length, S (mm) |
3,4,5,6±1
|
Reinforcing Tape
Length, B (mm) |
5,6,8,10,15,20±1
|
| UL Style/ File No. |
20798 / E188165 & 20861 / E146835
|
| Flame Retardant Test |
ULVW-1
|
| Rating |
80°C / 60V & 105°C / 60V
|
| Dielectric with Standing Voltage |
DC500V for 1 min.
|
Insulation Resistance
Between Conductors |
>100M 
(DC500V at 20°C)
|
| Humidity Test |
40°C, RH 95%, 96hours
|
| Flexibility Test |
Normal: More than 10,000 cycle
|
|
Abnormal: More than 10,000,000 cycle
|
| Ageing Test |
85°C, 96 hours
|
Specification Guide
|
Item
|
Selection
|
Consideration
|
| No. of Conductors |
4 ~ 50
|
No. of circuits required
|
| Conductor Pitch |
0.5mm
|
1.0mm
|
1.25mm
|
2.54mm
|
Space, PCB layout and FFC Connector pitch
|
| Conductor Size |
0.035x
0.3(mm)
|
0.1x0.7(mm)
0.035x0.7(mm)
|
0.1x0.8(mm)
0.05x0.8(mm)
|
0.1x0.8(mm)
0.1x1.27(mm)
|
Conductor resistance and
Flexing life
|
| Termination |
Solder-type
|
Solder to PCB
|
|
Insertion-type
|
Insert to FFC connector
|
| Configuration |
Type A,B,C,D
|
Insert to FFC connector
|
|
Orientation of FFC connector contact
|
|
Type E
|
One end to be soldered to PCB and the other end to be
inserted to FFC connector
|
|
Type F
|
Flexing position near to supporting tape edge
|
|
Type G
|
Both ends to be soldered
to PCB
|
| Overall length, L |
25 ~ 1,000mm
|
Dimensional requirement
|
| Strip length, S1,S2 |
3, 4, 5, 6 mm (Insertion-type)
|
FFC connector contact distance
|
|
3, 4, 5, 6 mm (Solder-type)
|
PCB solder pad size
|
| Reinforcing Tape Length, B1, B2 |
5, 6, 8, 10, 15, 20 mm (Insertion-type)
|
Connector dimension, operator insertion grip length,
flexing position
|
| Folding |
Up to user's design
|
Folding to meet layout requirement
|
Description:
PDF File
In Download |